1-12. Ringing of compulsory operation, compulsory frost removal buzzer
1) If pressing the test button in the main PCB,
“Phi ~” sound rings.
2) In selecting compulsory operation, alarm sound is repeated and completed in the cycle of On for 0.2 second and Off for
1.8 second three times.
3) In selecting compulsory frost removal, alarm sound is repeated and completed in the cycle of On for 0.2 second , Off for
0.2 second, On for 0.2 second and Off for 1.4 second three times.
1-13. Defrosting (Removing frost)
1) Defrosting starts each time the accumulated COMPRESSOR running time is between 7 and 50 hours. This time is
determinated by how often and how long the doors are opened.
2) For initial power on or for restoring power, defrosting starts when the compressor running tume reaches 4 hours.
3) Defrosting stops if the sensor tempreature reaches 41°F (5°C) or more. If the sensor doesn´t reach 41°F (5°C) in 1 hours, the
defrost mode is malfunctioning. (Refer to the defect diagnosis function, 8-1-15).
4) Defrosting won´t function if its sensor is defective (wires are cut or short circuited).
1-14. Sequential operation of built-in product
Built-in components such as the compressor, defrost removal heater, freezer compartment fan, Cooling Fan and step motor
damper are sequentially operated as follows to prevent noise and part damage from occurring during testing procedure.
Function Load Operation Sequence Remark
It si a load
movement
sequence in
case of the F/R
room closed.
If error occurs
during
operation,
initial
operation is
not done.
INITIAL POWER ON
•
0.3
sec.
0.3
sec.
0.3
sec.
0.3
sec.
0.3
sec.
0.3
sec.
0.3
sec.
0.3
sec.
0.3
sec.
Above 45°C
TEST MODE
Lower than 45°C
(In service)
TEST MODE1
TEST MODE 2
0.3
sec.
If pressing SW
once more in the
test mode 2 or
temperature of
defrost sensor
is more than 5°C
it returns to the
test mode for
initial operation
(comp operates
after 3 minutes).
0.3
Sec
10
Sec
5
Sec
0.3
Sec
5
Sec
0.3
Sec
5
Sec
60Sec
0.3
Sec
0.3Sec
0.3Sec
POWER
ON
POWER
ON
Defrost
H/T ON
Defrost
H/T OFF
PIPE
H/T ON
TEST SW
(PRESS
Once)
OTHER
LOADS
OFF
COMP
ON
F-FAN
&
C-FAN
ON
STEPPING
MOTOR
OPEN
PIPE
H/T OFF
Disp’
&
F Door
H/T
ON
H/Bar H/T
ON
H/Bar H/T
OFF
COMP
ON
DUCT
MOTOR
CLOSE
F-FAN
&
C-FAN
ON
STEPPING
MOTOR
ON
PIPE HTR
ON
Disp’
&
F Door
H/T
OFF
COMP
ON
F-FAN
C-FAN
ON
DAMPER
OPEN
TEST SW
(PRESS
2 times)
COMP
OFF
:In case of the defrost sensor
Temperature: +5°C↓
F-FAN
&
C-FAN
OFF
DEF
HEATER
ON
STEPPING
MOTOR
CLOSE