1-17. Failure Diagnosis Function
ERROR CODE on display control panel
To display the error message, press and hold Ice Plus button and Freezer button. If no errors are displayed, all LEDs will be
illuminated. If a primary or secondary error is present, certain LEDs will be illuminated indicating failure mode.
SECONDARY ERROR INDICATOR LIGHT
REFRIGERATOR SENSOR (2) (LOWER SENSOR
IN REFRIGERATOR COMPARTMENT) ..........................................”ICE PLUS” INDICATOR WILL NOT BE LIT
ROOM TEMPERATURE SENSOR .................................................”FREEZER TEMPERATURE LOWER” INDICATOR
HUMIDITY SENSOR .......................................................................”WATER” INDICATOR WILL NOT BE LIT
NOTE 1:
1) Errors are divided in primary and secondary errors.
2) Secondary errors only can be displayed by performing “DISPLAY LED CHECK”
pressing ICE PLUS & FREEZER buttons simultaneously for more than 5 seconds, If
all LED are turned ON, errors are not present.
3) When a primary error occurs in the refrigerator, this error will be showed by display
after 3 hours after first occurrence. Anyway, if you perform “DISPLAY CHECK LED”
you can see the error present in the unit, regardless the time elapsed from the first
occurrence.
1 Normality None Normal Operation of Display.
2
Freezer Sensor
Error
Short or Disconnection of
Freezer Sensor
3
Refrigerator
Sensor 1 Error
Short or Disconnection of
Refrigerator Sensor
4
Defrosting
Sensor Error
Short or Disconnection of
Defrosting Sensor
5
Refrigerator
Sensor 2 Error
Short or Disconnection of
Refrigerator Sensor 2
6
Room Temp
Sensor Error
Short or Disconnection of
Room Temp. Sensor
7 Poor Defrosting
Even though it is passed 1
hour since then Defrosting, if
Defrosting sensor is not over
+41ºF (5ºC), it is caused
Temperature Fuse
Disconnection, Heater
disconnection, DRAIN Jam,
Poor Relay for Heater
8
Abnormality of
BLDC FAN Motor
for Freezer
It is caused when feedback
signal isn't over 65 seconds
during BLDC FAN motor
operating
Poor BLDC Motor connection,
DRIVE IC and
TR
9
Abnormality of
BLDC FAN Motor
for Machinery
Room
It is caused when feedback
signal isn't over 65 seconds
during BLDC FAN motor
operating
Poor BLDC Motor connection,
DRIVE IC and TR
10
Communication
Error
Communication Error
between Micom of Main PCB
and Display Micom
Poor Communication
connection, Poor TR of
Thermistor and Receiver
Tx/Rx between display and
main board
11
Humidity Sensor
Error
Short or Disconnection of
Humidity sensor
Poor connection of housing,
missing Humidity sensor
,
sensor defect itself, short or
disconnection of harness
Check each sensor and its
connector
.
Error Detection
Category
NO
Error Display
Error Generation Factors Remarks