Refrigerator Troubleshooting Diagram

Archive for the ‘Evaporator pressure regulator’ tag

Refrigerator Evaporator Pressure Regulator

without comments

This valve is fitted in the suction line to control the pressure in the evaporator, to prevent it dropping below a predetermined pressure. It is used to control the evaporating temperatures of systems such as drinking water fountains and beverage coolers, to maintain a constant evaporator pressure/temperature and prevent freezing.

It is also used in multi-evaporator systems, when it is installed in the suction line of the warmest evaporator. Check valves or one-way valves are necessary to prevent migration of refrigerant from the warmer to the cooler evaporators during off cycles (see Figure 84).

refrigerator--check-valve

Written by sam

November 11th, 2009 at 8:45 pm