28
OPERATION PRINCIPLES BY PARTS OF CIRCUIT
5-12) BLDC MOTOR Circuit(RS2640, RS26VU)
1) This model has adopted a BLDC motor to reduce power consumptions and it is used for all of the F-Room, the
R-Room and the Unit Compartment. (This motor driving circuit is the common circuit used in other models.)
2) Operation Principle
Look at the above circuit. Then, it is quite obvious that the composition of the circuit is similar to one another.
Let’s take the F-Fan motor as an example. The Fan Motor operates in high or low speed according to
conditions. For the F-Fan to operate, a constant voltage should be applied to OP-AMP PIN #2 as shown in the
figure. When the voltage of MICOM #47 is 0V, the voltages of both its counter part and OP-AMP #2 are 0V. So,
the motor does not operate. When #47 becomes high (5V), the distributed voltage between R706 and R705,
which can be obtained by subtracting the forward direction drop voltage of the D706 (1N4148), will be applied
to OP-AMP #2. When this voltage is multiplied three (Gain Value set at present), you can get the voltage
applied to the motor. If the voltage of the OP-AMP #13 is 3V, the 9V (3Vx3) is applied to the motor. (When the
F-Fan is under High RPM conditions, the MICOM Pin #47 will be high (5V) and when the F-Fan is under Low
RPM conditions, the MICOM Pin #46 will be low high(5V). The MICOM Pin does not output High & Low
together at the same time. But, it outputs either High or Low, or it outputs all off (0V) and turns off the Fan. (The
same principle applies to the High/Low RPM of the C-Fan.)
Note) According to conditions, the F-Fan Motor and the Comp Fan Motor will be controlled to HIGH RPM or
LOW RPM.In general, it runs in high RPM when the fridge is frequently used and it runs in low RPM when
the fridge is being used less frequently. (For the improvement of its function, the RPM, Voltage and
Frequency can be changed without any notice in advance.)
3) When error occurs with the motor (when its RPM is detected as lower than 600 ~ 700 RPM), the relevant motor
will stop immediately and it will run again in 10 seconds. At this time, if the motor RPM is input correctly, it will
be evaluated as normal and keep on its operation. But, if a correct RPM is not input with a start-up after 10
seconds, it will stop and start up again in 10 seconds. When it won't operate normally after repeating stop and
start-up for 5 times, it will pause for 10 minutes and then will repeat the 5-time stop & start-up and the 10-
minute pause. During the above, when the Self Diagnosis is selected on the display panel, it will show that
there is an error with the motor by blinking the LED relevant to the motor. When power goes off, data for errors
will be deleted. So, do not turn off power before it is checked by our service personnel.
Note) When the abnormal operation or stopping of the Fan Motor is expected, do not turn off power. Run the
Self Diagnosis and check if there is any error.