45
Appendix
ⅠⅠ
(Reference for circuit diagnostics)
LOAD
TERMINALS PCB CASE
VALUE
DEFECTS OTHERS
DISPENSER HEATER
1) DEFROST HEATER
2) ICE PIPE HEATER
CN72 ① & ③
CN71 ⑦ & ①
VALUE FOR
NORMAL HETAER
VALUE FOR
NORMAL HETAER
DISPENSER MODEL
(EXTERNAL)
0Ω
∞Ω
0Ω
∞Ω
THERMAL FUSE, HEATER, WIRE SHORT
THERMAL FUSE, HEATER, WIRE SHORT
HEATER, WIRE SHORT
HEATER, WIRE CUT OR HOUSING SLIPPED AWAY
COIL, WIRE SHORT
COIL, WIRE CUT
COIL, WIRE SHORT
COIL, WIRE CUT
COIL, WIRE SHORT
COIL, WIRE CUT
COIL, WIRE SHORT
COIL, WIRE CUT
ICE SOLENOID
VALVE
CN70 ⑤ &
CN71 ①
0Ω
∞Ω
WATER
SOLENOID VALVE
CN70 ⑦ &
CN71 ①
0Ω
∞Ω
AUGER MOTOR
CN70 ① &
CN71 ①
0Ω
∞Ω
CUBE
SOLENOID VALVE
CN70 ③ &
CN71 ①
0Ω
∞Ω
Turn off the power, disassemble the Housing connected to the MAIN PCB CN70, 71 & 72 and measure the
followings
LOAD RELAY TERMINALS VALUE WHEN IT IS DIFFERENT FROM MEASURED VALUE
DEFROST /
COMP OFF
RY75 / RY76
SUPPLY
VOLTAGE(SV)
CN71⑦-⑤
RY75
SV
CN71⑨-⑤
COMP ON
RY75/RY76
SV
CN71⑦-⑤
RY75
0V
CN71⑨-⑤
DEFROST
CUBE & AUGER
MOTOR OFF
CUBE & AUGER MOTOR
OPERATING
WATER SOLENOID
VALVE OPERATING
ICE SOLENOID
VALVE OPERATING
RY75 / RY76
0V
CN71⑦-⑤
SV
CN71⑨-⑤
RY76 CONTACT SHORT, FAULTY DRIVING CIRCUIT
RY75 NO CONTACT SHORT, FAULTY DRIVING CIRCUIT
FAULTY RY75 / RY76 NO CONTACT SHORT, FAULTY
DRIVING CIRCUIT
RY75 NO CONTACT OPEN, FAULTY DRIVING CIRCUIT
FAULTY RY76 /
RY75 NC CONTACT OPEN, FAULTY DRIVING CIRCUIT
RY75 NO CONTACT SHORT, FAULTY DRIVING CIRCUIT
RY73 & RY74 NO CONTACT SHORT, FAULTY DRIVING CIRCUIT
RY74 NO CONTACT SHORT, FAULTY DRIVING CIRCUIT
RY73 OR RY74 NO CONTACT OPEN, FAULTY DRIVING CIRCUIT
RY74 NO CONTACT OPEN, FAULTY DRIVING CIRCUIT
RY71 NO CONTACT OPEN, FAULTY DRIVING CIRCUIT
RY72 NO CONTACT OPEN, FAULTY DRIVING CIRCUIT
Turn on the power and check the status of the Relay & the Driving Circuit by checking the followings according
to the operation of loads.
RY75
SV
CN71⑤∼CN70③
RY73 / RY74
SV
CN71⑤∼CN70①
RY74
0V
CN71⑤∼CN70③
RY73 /RY74
0V
CN71⑤∼CN70①
RY74
0V
CN71⑤∼CN70⑦
RY71
0V
CN71⑤∼CN70⑤
RY72