1-10
Basic Information
PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT 37°/0°
CONTROL SETTING
Variable Speed Compressor 65°F (18°C) Ambient 90°F (32°C) Ambient
Operating Time 32 to 40% 100%
Freezer Temperature
-6° to 6° F
-21° to -14° C
-6° to 6° F
-21° to -14° C
Refrigerator Temperature
33° to 46° F
0.5° to 8° C
33° to 46° F
0.5° to 8° C
Low Side Pressure
(cut-in)
5 to 12 psig
34 to 83 kPa
N/A
Low Side Pressure
(cut-out)
-2 to 2 psig
-14 to 14 kPa
-2 to 2 psig
-14 to 14 kPa
High Side Pressure
85 to 95 psig
586 to 655 kPa
120 to 135 psig
827 to 931 kPa
Wattage 40 to 55 60 to 70
Amps (running) .5 to 1.1 .7 to .9
Base Voltage 115 vac (127 vac max)
DEFROST SPECIFICATIONS
Cabinet Size
Thermostat Heater
Cut-in Cut-out Watts Ohms
26’ & 28’ SD, 23’ CD
25° F
(-4° C)
47° F
(8° C)
500 26
Electronic Timer - (ADC) Defrost 24 minutes every 6-96 hours of compressor run time.
CONDENSER FAN MOTOR
Watts RPM Amps
3.1
(Energy Star, some models)
1100 CW
Opposite Shaft
0.03 Running
ICE MAKER SPECIFICATIONS
Electrical 115 vac (127 vac max)
Thermostat Opens at 48° F (9° C), Closes at 15° F (-9° C)
Heater Voltage 85 vac
ICE MAKER CONNECTOR PLUG CONNECTIONS
Wire Number Wire Color Connects to:
1 Green/Yellow Ground
2 Yellow Water Valve
3 Black Line
4 Light Blue Neutral
Models With Freezer Compartment Ice Maker And Without Dispenser