41
TROUBLESHOOTING
※ TEST MODE KEY
-. RF221, RF220, RL225 Model : Ice Off + Fridge Key
-. RL220 Model : Power Freeze + Fridge Key
1-3) If manual operation works, compressor & f-fan operate continuously for 24 hours and fresh food
compartment will be controlled by the setting temperature.
1-4) When the manual operation runs, setting temperature will be selected automatically as below: freezer
compartment 7-degree, fresh food compartment 7-degree.
1-5) During manual operation, Power Freezer function will not be work. If a function is selected, the power
function icon of the selected function will be off automatically after 10 Seconds.
1-6) Manual operation can be canceled by removing power from the unit, then resupplying power.
1-7) Alarm(0.25 sec ON/ 0.75 sec OFF) will beep continuously until manual operation is completed and there is
no function to make the sound stop.
2-1) When you press any key one more time at Forced Operation , F/R Panel LED 1~4 ON. At this time, the
Force Operation stops immediately and F-Defrost will be performed at the same time.
2-2) At this time, it will send out “Beep” sound for 2 seconds and then it will perform Forced F Defrost while
sending out “0.5 sec On and 0.5 sec Off” sound.
3-1) During the simultaneous defrosting of freezer compartments, if the display panel change to the test mode
and test button is pressed one more time, defrosting of freezer compartments will be canceled and the
unit will return to the normal operation. Or, all test functions will be canceled by turning main power ON
and OFF.
2) Forced Defrost
3) Test cancel mode