47
TROUBLESHOOTING
Error Code Part Display Criteria To check if the part is normal
The F compartment
abnormal high-
temperature indicator
blinks
When the freezer temperature is abnormally
high or the freezer door is open for a
certain period of time and the freezer
temperature increases, the freezer display
blinks.
The temperature has been abnormally increased. Check
if the door has been open for a long time or if hot food
has been stored in the compartment. If the reason for
the error is removed, the error code disappears after a
pre-determined period of time.
The R compartment
abnormal high-
temperature indicator
blinks
When the freezer temperature is abnormally
high or the fridge door is open for a certain
period of time and the fridge temperature
increases, the fridge display blinks.
Check if the door has been open for a long time or if hot
food has been stored in the compartment. If the reason
for the error is removed, the error code disappears after
a pre-determined period of time.
F Comp start failure
error
The error code is displayed when the
compressor has failed to start.
Check the soldering status of the inverter PCB. (Check
if any parts have short-circuited). Check if the DC
15V output is less than 13.5V. Check the Comp and
Cycle.
F Comp IPM Fault
Error
The error code is displayed when the
compressor IPM fault error has occurred.
F Comp location
detection error
The error code is displayed when the
compressor location detection failed.
Check the compressor wire connections. Check the
soldering status of the inverter PCB. (Check if any parts
have short-circuited). Check the Comp and Cycle.
F Comp motor
constraint error
The error code is displayed when the
compressor motor is constrained.
Check if the compressor and the Cycle is normal.
Check the input voltage. Check the soldering of the
inverter PCB. (Check if any parts have short-circuited.)
F Comp low voltage
error
The error code is displayed when the AC
Input Voltage is too low.
Check the input voltage. (This error occurs when the
input voltage is AC 106 V or lower.)
F Comp over voltage
error
The error code is displayed when the AC
Input Voltage is too high.
Check the input voltage. (This error occurs when the
input voltage is AC 310V or higher.)
R Comp start failure
error
The error code is displayed when the
compressor has failed to start.
Check the soldering status of the inverter PCB. (Check
if any parts have short-circuited). Check if the DC 15V
output is less than 13.5V. Check the Comp and Cycle.
R Comp IPM fault error
The error code is displayed when the
compressor IPM fault error has occurred.