59
TROUBLESHOOTING
4-2-2. When the F Room Compressor(ENV2) is not operating (F Room Inverter, LC3-3A)
10 minutes have passed since the COMP
was turned off
Check after 10 minutes
The Forced Operating signal sound
should be checked
Check the wire harness Replace
the Main PCB
Replace the Inverter PCB
When Forced Operating mode is activated,
the COMP operates
The COMP operating signal (CN103
④↔⑥) is High (about DC 2-2.5V)
Is DC 15V applied to ZD501?
The COMP Connector (CN04) is Good
Check the COMP Wire
Check the Compressor
Replace the COMP ASS'Y
Normal (Recheck)
No
No
Yes
Yes
No
No
Yes
Yes
Yes
No
Yes
No
Yes
Replace the
F-Sensor.
Repair the sensing
part or Replace
the Main PBA
Yes
Yes
The F-Sensor is Good
The temperature sensing part of the MAIN
PBA is Good
Replace the Main PBA or
Repair the connection
No
No
Start
The COMP ASS'Y is Good
When the inverter PCB LED
is ON, it indicates that the
compressor is operating
normally
Refer to the TEST Function in
this manual
0~800Hz 50% Duty Signal
Output