MICOM FUNCTION
2-15. Failure Diagnosis Function
1. Failure diagnosis facilitates service when a failure code shows during product operation.
2. When a failure is detected, the buttons are deactivated.
3. If a failure code is released, the MICOM resets and normal operation continues.
4. The failure code is displayed on the display screen. All display graphics that are not part of the failure code are turned off
(1) GR-G277STSA(LSC27990TT)
NO
1 ABNORMAL
FREEZER SENSOR
ABNORMAL£EFRIGERATOF
SENSORI(RI/
2 UPPER PART IN THE
REFRIGERATOR
COMPARTMENT_
ABNORMALREFRIGERATOR
SENSOR2(R2)
3 LOWER PART IN THE
REFRIGERATOR
COMPARTMENT)
4 ABNORMAL
DEFROST SENSOR
ITEM
5 FAILEO BEFROSTING
6 ABNORMALFREEZING
BLOC MOTOR
7 ABNORMALCOOLING
BLBC MOTOR
FAILURE CODE
INDICATION PART
FREEZERROOM NOTCH REFRIGERATORROOMNOTC
TEMPERATUREDISPLAY TEMPERAqJREDISPLAY
Er FS
Er rS
CONTENTSOF FAILURE
NORMAL DISPLAY (NOTE 2)(See Pace 19)
Er dS
Er dH
Er FF
Er CF
Er CO
NORMAL DISPLAY (NOTE 1)(See pac e 19)
NORMAL DISPLAY (NOTE 2) (See PaCe 19 )
NORMAL OlSFLAY (NOTE 2) (See Pace 19)
FREEZER SENSOR
SHORTCIRCUIT
REFRIGERATOR SENSOR 1
SHORT CIRCUIT
REFRIGERATOR SENSOR 2
SHORT CIRCUIT
ABNORMAL SHORT CIRCUIT
DEFROST HEATER,
TEMPERATURE FUSE SHORT
CIRCUIT, UNPLUGGED
CONNECTOR(INDICATED
4 HOURLATER AFTER TROUBLE)
MOTORDEFECT HOOKEDOF LEAS
WIRETOFAN,CONTACTOF
STRGCTRES WITHFAN SHORTOR
OPEN OFLEADWIRE(THEREIS
NOSIGNALOF BLOCMOTORMORE
THAN115SECONDSINOPERATION
OFFANMOTOR}
SHORT OR OPENOF LEAS WIRE
CONNECTINGBETWEEN MAIN PCE
AND DISPLAYPCB, TRANSMISSION
TB AND RECEIVINGPART
© : PROPEROPERATION
PRODUCT OPERATION STAUS IN FAILURE
COMPRESSOR
ONFOR15MINUTES/
OFFFOR15MINUTES
©
FREEZINGBLOC
MOTOR
O
O
O
O
O
O
©
O
O
STANDARD RPM
STANDARD RPM
COOLINGBLDC
MOTOR
STANDARD RPM
STANDARD RPM
STANDARD RPM
OFF
STANDARD RPM
STANDARD RPM
O
O
O
DEFROST
HEATER
O
O
O
O
OFF
0
0
0
0
STEPPING MOTOR
DAMPTER
Q
NO DEFROST
O
©
O
0
©
O
O
FULLOPENINGFOR10MINUTES/
FULLCLOSINGFOR1S MINUTES
O
O
O
O
O
ABNORMAL
8 COMMUNICATION C_
9 ABNORMAL AMBIENTSENSOR SHORT
AMBIENT SENSOR CIRCUIT ©
10 ABNORMAL WATER TANK SENSOR ©
WATER TANK SENSOR SHORT CIRCUIT
11 ABNORMAL OPTICHILLSENSOR 0
OPTICHILL SENSOR SHORT CIRCUIT
-18-