MICOM FUNCTION
2-16. Test Function
1. The test function assists in diagnosing the PWB and determining the exact mode of failure.
2. The test button is on the main PCB. When test mode is engaged, it will complete its test cycle and default to normal
operation within 2 hours.
3. The buttons are disabled while the test mode is in effect.
4. When you have finished running test mode, unplug the refrigerator to reset it to normal operation.
5. If a failure is detected during test mode, release the test mode to display the failure code.
6. If a failure code is displayed, the test mode cannot be started.
Mode
Test 1
Test 2
Operation
Press test button once
(strong cold mode)
Press test button once at
the test mode 1 status
(forced defrost mode)
1,
2.
3.
4.
5.
6.
1.
2.
3.
4.
5.
Contents
Continuous operation of compressor
Continuous operation of freezing BLDC motor
(high-speed RPM) and cooling BLDC motor
Defrost heater turns off
Stepping motor damper is completely opened
(baffle is closed)
OptiFresh stepping motor damper is
completely closed.
All display LCD graphics turn on.
Compressor OFF
Freezing BLDC motor and cooling BLDC
motor turn off
Defrost heater turns on
Stepping motor damper is completely closed
(baffle is closed)
OptiFresh stepping motor damper is
completely closed.
Remarks
Freezer fan turns off when
door is opened.
Return to the normal mode
when the defrost sensor is
above +5°C (+41 °F)
Normal Press test button once at Return to the initial status. Compressor will operate
Status the test mode 2 status after delay for 7 minutes
<TEST MODE 1> <TEST MODE 2>
- 20 -