EXPLANATION FOR MICOM CIRCUIT
1-12. Temperature compensation and temperature compensation circuit
1. Temperature compensation in freezer and refrigerator
(1) GR-G277STSA(LSC27990TT)
TRI7R_ _>EOK Temperaturecompensationat refrigerator 56
_-,R_,F_- _ _ ternperaturecornpensationatfreezer57
]CL
[AINO}
P61
tAINH
Freezer Refrigerator
Resistance value Temperature Resistance value Temperature Remarks
(RCF1) compensation (RCR1) compensation
180 k_-2 +5 °C [+9°F] 180 k_-2 +2.5 °C [+4.5°F] Warmer
56 k_-2 +4 °C [+7.2°F] 56 k_-_ +2.0 °C [+3.6°F]
33 k_-2 +3 °C [+5.4°F] 33 k_-_ +1.5 °C [+2.7°F] ' ,
18 k_-2 +2 °C [+3.6°F] 18 k_-_ +1.0 °C [+1.8°F]
12 k_-2 +1 °C [+1.8°F] 12 k_-_ +0.5 °C [+0.9°F]
10 k_-2 0 °C [O°F] 10 k_-_ 0 °C [O°F] Referencetemperature
8.2 k_-_ -1 °C [-1.8°F] 8.2 k_-_ -0.5 °C [-0.9°F]
5.6 k_-_ -2 °C [-3.6°F] 5.6 k_-_ -1.0 °C [-1.8°F]
3.3 k'_ -3 °C [-5.4°F] 3.3 k'_ -1.5 °C [-2.7°F] ,
2 k'_ -4 °C [-7.2°F] 2 k'_ -2.0 °C [-3.6°F]
470 _-2 -5 °C [-9°F] 470 _-2 -2.5 °C [-4.5°F] Cooler
1_Temperature compensation table by adjustment value (difference value against current temperature)
Ex) If you change compensation resistance at a refrigerator (RCR1) from 10 k_-2(current resistance) to 18 k_-2(modified
resistance), the temperature at the refrigerator will increase by +1°C[+1.8°F].
-31 -