TROUBLE DIAGNOSIS
CLAIMS. HOW TO CHECK
4. Warm
refrigerator
compartment
temperature.
5. No automatic
operation.
(faulty
contacts)
6. Condensation
and ice
formation.
CAUSES AND CHECK POINTS.
1) Clogged cooling path.
Adiabaticsliquidleak?.
Foreignmaterials.- Adiabaticsdump liquid
2) Food storage. Storehotfood.
Storetoomuchat once.
Dooropen.
Packagesblockairflow.
1) Faulty temperature sensor in freezer or refrigerator compartment.
_ Faulty contact.
Faultytemperaturecharacteristics.
2) Refrigeration load is too much. Food. ,Toomuchfood.
L Hotfood.
Frequentopeningandclosing.
Coolairleak.
Poordoorclose.- Partlyopens.
3) Poor insulation.
4) Bad radiation. _ Highambienttemperature.
Insufficientspacearoundrefrigertor.
5) Refrigerant leak.
6) Inadequate of refrigerant.
7) Weak compressor discharging power. _ Differentrating.
Smallcapacity.
8) Fan does not work.
9) Button is set at strong.
1) Ice in freeezer compartment.
External airinflow. -- Bushing installed incorrectly.
Dooropens Weakdoorclosingpower.
butnotcloses. Stoppermalfunction.
Doorsag.
Foodhindersdoorclosing.
Gaparoundgasket.-- Contraction,distortion,loose,doortwisted,corner not
fullyinserted.
Foodvapor. -- Storinghotfood.-- Unsealedfood.
2) Condensation in the refrigerator compartment.
Dooropens Insufficientclosing.
butnotcloses. Doorsag.
Foodhindersdoorclosing.
Gasketgap.
3) Condensation
Coolairleak
andtransmitted.
on liner foam.
Notfullyfilled.• Toptablepart.
L OutplateRef/Lowerpart.
Flangegap.-- Notsealed.
Gasketgap.
• Inspect parts measurements
and check visually.
- 54 -