LED turn on to indicate option selected
1-18. Test Function
1) The purpose of test function is to check function of the PCB and product and to search for the failure part at the failure
status.
2) Test button is placed on the main PCB of refrigerator (test switch), and the test mode will be finished after maximum 2 hour
for Test mode 1, 80minutes for Test mode 2.
3) Function adjustment button is not perceived during performance of test mode.
4) In finishing test mode, always pull the power cord out and then plug-in it again for the normal state.
5) If non conforming contents such as sensor failure are found during performance of test mode, release the test mode and
display the failure code.
6) Even if pressing the test button during failure code display, test mode will not be performed.
1-19. Filter cartridge status reset button
1) While the Freezer Door is opened. Dispenser function can not be used.
2) There are one dispenser pad.
3) You can select 3 options to be dispensed (Cubed ice / crushed ice / water).
4) Push the dispensing pad, and the selected option will be dispensed.
5) Dispensing function won’t work if LOCK mode is enabled.
6) When CUBED or CRUSHED ice is selected, at press the dispensing pad, a duct door motor will be opened, and this motor
will close automatically after 5 seconds from you release the pad, during the operation of this function, the AUGER MOTOR
will be working in two ways (CW or CCW) depending if you selected CUBED ICE or CRUSHED ICE, the AUGER MOTOR
stops immediately after you release the pad.
7) When water dispensing option is enabled, WATER & PILOT VALVE will be activated, and this will stop immediately after
you release the pad.
1-20. Smart Diagnosis system
1) Open the R door.
2) Lock the display (refer to
3)
4)
1-4. Key Lock Button).
To activate this mode press and hold FREEZER button over 5 seconds.
The buzzer will ring
*NOTE: This function will be required only when the customer called to Service Center.
with the recognition sound of three “Ding~” and four tone sequence.
5) The display will start a countdown of 3 seconds.
6) At the end, the display will return to normal mode.
Compressor will turn ON after a 3 min delay, Freezer Fan 8 min and Stepping
Return to the normal mode when the defrost
sensor is above +41°F (5°C).
Motor 13 min.