TROUBLESHOOTINGTROUBLESHOOTING
4-2-17. LED blinking frequency depending on protecting functions4-2-17. LED blinking frequency depending on protecting functions
If Failure Condition is detected during compressor is operating, immediately stopIf Failure Condition is detected during compressor is operating, immediately stop
Compressor operating and stand by 5 minutes. During this 5 minutes, RPM commandCompressor operating and stand by 5 minutes. During this 5 minutes, RPM command
signal is not available. It means, even if available RPM command signal is applied tosignal is not available. It means, even if available RPM command signal is applied to
the compressor, it does not work and keep standing the compressor, it does not work and keep standing
LED blinking frequency depending on protecting functionsLED blinking frequency depending on protecting functions
If the same blinking, After 5 If the same blinking, After 5
minutes, Follow the Remarksminutes, Follow the Remarks
Blinking time is 1 second and dwell Blinking time is 1 second and dwell
time is 2 seconds.time is 2 seconds.
LED Blinking FrequencyLED Blinking Frequency
1. Short between COMP U,V 1. Short between COMP U,V
and W Phase (CN102)and W Phase (CN102)
2. Short among IPM Pins (No. #1 ~ 26)2. Short among IPM Pins (No. #1 ~ 26)
3. Drop the IPM operating Voltage under DC 13.5V3. Drop the IPM operating Voltage under DC 13.5V
4. Other cases, check the COMP, cycle, etc.4. Other cases, check the COMP, cycle, etc.
1. Open the COMP wire (CN102)1. Open the COMP wire (CN102)
2. Bad condition of R1(ex. Bad soldering)2. Bad condition of R1(ex. Bad soldering)
3. Other cases, check the COMP, cycle, etc.3. Other cases, check the COMP, cycle, etc.
1. Operating the locked rotor COMP within 5 second.1. Operating the locked rotor COMP within 5 second.
2. Operating the COMP under 1,000 RPM 2. Operating the COMP under 1,000 RPM
3. Occur the huge change of input voltage in a3. Occur the huge change of input voltage in a
4. Other cases, check the COMP, cycle, etc.4. Other cases, check the COMP, cycle, etc.
1. Drop the input voltage under AC 53V1. Drop the input voltage under AC 53V
2. Short resistor R525 (DC link Resistor)2. Short resistor R525 (DC link Resistor)
1. Increase the input voltage over AC 155V1. Increase the input voltage over AC 155V
2. Short resistor among R522, R523 and R524 (DC2. Short resistor among R522, R523 and R524 (DC
Link Resistor)Link Resistor)
CommunicationCommunication
1. Check Terminal CN1031. Check Terminal CN103
2. Short or Open resistor R210, R2122. Short or Open resistor R210, R212
3. Short or Open harness between Main and Inverter3. Short or Open harness between Main and Inverter