TROUBLESHOOTINGTROUBLESHOOTING
R Self-diagnostics check listR Self-diagnostics check list
Pantry-Damper-Pantry-Damper-
Display error when open error is detectedDisplay error when open error is detected
by damper heater : separation of Damperby damper heater : separation of Damper
Heater housing part, contact error,Heater housing part, contact error,
disconnection, short circuit.disconnection, short circuit.
After separating MAIN PCB CN77 wire fromAfter separating MAIN PCB CN77 wire from
PCB, resistance value between Black ↔ BrownPCB, resistance value between Black ↔ Brown
wire shall be 135 ohm± 7%.wire shall be 135 ohm± 7%.
0 ohm : heater short, ∞ Ohm : wire / bimetal0 ohm : heater short, ∞ Ohm : wire / bimetal
FZ-Ice Pipe HeaterFZ-Ice Pipe Heater
The error occurs when there is a wireThe error occurs when there is a wire
connector slip-out of the Water Supplyconnector slip-out of the Water Supply
Pipe Heater, a contact error or aPipe Heater, a contact error or a
breakage in the wiring.breakage in the wiring.
When measuring the resistance of the MainWhen measuring the resistance of the Main
PCB CN79 Yellow-Pink wires, it should bePCB CN79 Yellow-Pink wires, it should be
within 102Ω ±7%.within 102Ω ±7%.
0Ω : heater short, ∞Ω : Check for Wire Open0Ω : heater short, ∞Ω : Check for Wire Open
or Connector Slip-outor Connector Slip-out
Ice Maker(FF) FunctionIce Maker(FF) Function
Display error when open error is detectedDisplay error when open error is detected
by Heater : separation of Ice Pipe Heaterby Heater : separation of Ice Pipe Heater
housing part, contact error, disconnection,housing part, contact error, disconnection,
short circuit.short circuit.
After changing the Ice Maker(R), plug theAfter changing the Ice Maker(R), plug the
refrigerator power code again, and check therefrigerator power code again, and check the
Ice Room-FAN ErrorIce Room-FAN Error
Display error during operation ofDisplay error during operation of
applicable fan motor : Feed back signalapplicable fan motor : Feed back signal
line contact error rnotor wire separationline contact error rnotor wire separation
When measuring the voltage between theWhen measuring the voltage between the
Main PCB CN76-"2" ↔ CN76-"1", it should readMain PCB CN76-"2" ↔ CN76-"1", it should read
between 7.0V~12V.between 7.0V~12V.
Communication ErrorCommunication Error
Display pc - Er in the panel with alarm :Display pc - Er in the panel with alarm :
MICOM MAIN ↔ PANEL communicationMICOM MAIN ↔ PANEL communication
Actually, If there is not a problem, it is desirableActually, If there is not a problem, it is desirable
to replace Main and Panel PCB With theto replace Main and Panel PCB With the
oscilloscope after a cable problem confirming.oscilloscope after a cable problem confirming.
Main - InverterMain - Inverter
Communication ErrorCommunication Error
Display 44Er in the panel :Display 44Er in the panel :
Inverter MICOM ↔ Main MICOMInverter MICOM ↔ Main MICOM
communication error.communication error.
Actually, If there is not a problem, it is desirableActually, If there is not a problem, it is desirable
to replace Main and Inverter PCB With theto replace Main and Inverter PCB With the
oscilloscope after a cable problem confirming.oscilloscope after a cable problem confirming.
Communication ErrorCommunication Error
Display 46Er in the panel :Display 46Er in the panel :
I/O Expander↔ Main MICOMI/O Expander↔ Main MICOM
communication error.communication error.
It is desirable to replace Main PCB.It is desirable to replace Main PCB.
FF Ice Duct HeaterFF Ice Duct Heater
The Error will be displayed when the IceThe Error will be displayed when the Ice
Duct Heater is detected as being openDuct Heater is detected as being open
due to the followings.due to the followings.
- Ice Maker Duct Heater Connector Slip-- Ice Maker Duct Heater Connector Slip-
Out, Contact Defect or Wire-BreakageOut, Contact Defect or Wire-Breakage
The resistance between CN79 ORG and CN51The resistance between CN79 ORG and CN51
BRN on the Main PCB shall be within 135Ω ±BRN on the Main PCB shall be within 135Ω ±
7%. And, when the resistance reads 0Ω or ∞7%. And, when the resistance reads 0Ω or ∞
Ω, check the followings.Ω, check the followings.
0Ω : Heater Short0Ω : Heater Short
∞Ω : Wire-Breakage or Wire Slip-Out∞Ω : Wire-Breakage or Wire Slip-Out
FF Ice Room HeaterFF Ice Room Heater
The Error will be displayed when the IceThe Error will be displayed when the Ice
Ice Room Heater is detected as beingIce Room Heater is detected as being
open due to the followings.open due to the followings.
Ice Room Heater Connector Slip-Out,Ice Room Heater Connector Slip-Out,
Contact Defect or Wire-Breakage.Contact Defect or Wire-Breakage.
The resistance between CN79 ORG and BRNThe resistance between CN79 ORG and BRN
on the Main PCB shall be within 135Ω ±7%.on the Main PCB shall be within 135Ω ±7%.
And, when the resistance reads 0Ω or ∞Ω,And, when the resistance reads 0Ω or ∞Ω,
check the followings.check the followings.
0Ω : Heater Short0Ω : Heater Short
∞Ω : Wire-Breakage or Wire Slip-Out∞Ω : Wire-Breakage or Wire Slip-Out
Comp starting FailureComp starting Failure
When the Compressor fails startingWhen the Compressor fails starting
Check if there is a short between compressorCheck if there is a short between compressor
terminals. Check IPM Voltage [Under 13.5V]terminals. Check IPM Voltage [Under 13.5V]
Check if there is a short between IPM PinsCheck if there is a short between IPM Pins
Check the Compressor and the CycleCheck the Compressor and the Cycle
Comp AbnormalComp Abnormal
current Detectioncurrent Detection
When ther is abnormal crrunt detected atWhen ther is abnormal crrunt detected at
the Compressorthe Compressor
Check the Compressor connections Check theCheck the Compressor connections Check the
voltage of Resistance of R308voltage of Resistance of R308
[0.09Ohm] Check the Compressor and the[0.09Ohm] Check the Compressor and the
Motor Locked OverMotor Locked Over
When there is a Compressor restrictiWhen there is a Compressor restricti
Check the voltage of Resistance of R308Check the voltage of Resistance of R308
[Short/Open] Check the voltage of both of[Short/Open] Check the voltage of both of
C103 terminals [Unstable Voltage] Check theC103 terminals [Unstable Voltage] Check the
Compressor and the CycleCompressor and the Cycle
Comp under voltageComp under voltage
When there is a low voltage errorWhen there is a low voltage error
Check the voltage of Resistance of Check the voltage of Resistance of
Comp over voltageComp over voltage
When there is a over voltage errorWhen there is a over voltage error
Check the voltage of Resistance of R501, R505,Check the voltage of Resistance of R501, R505,